furse three-phase power SPD ESP480
ESP480C ESP480M1 |
SPD Model: ESP480 ESP480C ESP480M1 Applications: suitable for buildings and Central Office power lightning protection, a wider range of voltage fluctuations, instability in the region designed specifically for the power supply voltage arrester.
Features: Low-Yun-voltage, easy installation, full protection, long service life, maintenance-free.
Status Indicator: ● ● ● alarm complete protection. Protection performance has been reduced, should be replaced as soon as possible ● unprotected immediate replacement.
Lightning Arrester Technical parameters:
Voltage
ESP 480 ESP480C ESP480M1
Normal voltage(RMS)
440 415V
Voltage(RMS)
346-484V 346~484V
Frequency range
40~60Hz 40~60Hz
Current (direct access)
0~100A 0~100A |
fuese three-phase power supply arrester ESP415
FURSE single-phase power supply arrester ESP240 |
SPD Model: ESP415 ESP240 Applications: suitable for buildings and Central Office power to protect against lightning. Features: Low-voltage, easy installation, full protection, long service life, maintenance-free.
Status Indicator: ● ● ● alarm complete protection. Protection performance has been reduced, should be replaced as soon as possible ● unprotected immediate replacement.
Technical parameters:
Voltage
ESP 240 ESP 415
Normal voltage(RMS)
240V 415V
Voltage(RMS)
200~280V 346~484V
Frequency range
40~60Hz 40~60Hz
Current (direct access)
0~100A 0~100A
Series fuse
100A 100A
Peak discharge current
40KA 40KA
Leakage current (relatively)
<60μA <60μA
Temperature
-40℃~+70℃ -40℃~+70℃
Connection cable 16mm2
16mm2 |
Power lightning protection device working status indicator |

FURSE three-phase power SPD ESP415M1
FURSE single-phase power SPD ESP240M1 |
Arrester Model: ESP415M1 ESP240M1
Applications: Suitable for important structures, the total power supply and lightning protection power supply main engine room.
Features: Low-Yun-voltage, easy installation, full protection, the right to the use of Shou-voltage alarm
Inochinaga, SovtripTM technology, status indicators, maintenance-free.
Status Indicator: ● ● ● alarm complete protection. Protection performance has been reduced as soon as possible
Replacement ● unprotected immediately replaced.
Technical parameters:
Voltage
ESP 240M1 ESP 415M1
Normal voltage (RMS)
240V 415V
Operating Voltage (RMS)
200~280V 346~484V
Frequency range
40~60Hz 40~60Hz
Current (direct access)
<100A <100A
Series fuse
100A 100A
Peak Discharge (conductors)
50KA 50KA
Maximum Discharge-to-ground
100KA 200KA
Operating current (normal)
<10mA <10mA
Leakage current (relatively)
<60μA <60μA
Temperature
-40℃~+70℃ -40℃~+70℃
Connection cable
16mm2 16mm2 |
SPD Status Indicator |
Lightning protection installation diagram |

furseThree-phase power arrester ESP 415M4
furseThree-phase power arrester ESP
415M2 |
Power Supply Arrester Model: ESP415M2 ESP415M4
Application scope: suitable for installation in large buildings in the total power within the large central room lightning protection and lightning protection power supply.
Features: Low-Yun-voltage, easy installation, full protection against ground-voltage warning, the use of
Long life, SovtripTM technology, status indicators, maintenance-free, failure alarm.
Status Indicator: ● ● ● alarm complete protection. Protection performance has been reduced as soon as possible
Replacement ● unprotected immediately replaced.
Voltage ESP 415M2 ESP 415M4
Normal voltage (RMS) 415V
415V
Operating Voltage (RMS) 346~484V
346~484V
Frequency range
40~60Hz 40~60Hz
Current (direct access) 0~200A 0~315A
Series fuse >200A >315A
Peak Discharge (conductors) 60KA 120KA
Maximum Discharge-to-ground 240KA 480KA
Operating current (normal) <20mA <40mA
Leakage current (relatively) <500μA <1000μA
Temperature -40℃~+70℃ -40℃+70℃
Connection cable 25mm2 50mm2 |
SPD Status Indicator |
Lightning protection installation diagram |
ESP Power lightning protection device ESP240-5A ESP240-16A |
Arrester Model: ESP240-5A ESP240-16A Applications: suitable for a single valuable equipment power mine.
Features: Low-Yun-voltage, easy to install and provide precise protection.
Technical parameters:
Normal voltage 240V
Voltage
200~280V
Allow voltage
590V(8/20us Waveform)
Bandwidth
40-60Hz
Maximum Current 5A
Peak discharge current
10KA(8/20us Waveform)
Leakage
<0.5mA
Temperature -40℃~+70℃
Connection details
Phase, medium-to input and output connections 2.5mm2
Cable connector (B1 type)
using Ф4.8-8mm cable
Grounding
M6 ground or ground with the head end |