           PTX048-3Y201/PTE048-3Y201 
           PTX048/PTE048 
           PTX048-3Y201-D/SD 
           PTE048-3Y201-D/SD 
              
             
             | 
        Summary of technical parameters  
          Pass the peak flow capacity: Each phase   48KA, each model 24KA ANSI / IEEE C62.41 placement: A and B  
          Applications:   surge in the level of activity to lower areas, sensitive / important electrical   loads including the allocation of cabinet, counter and important user load   distribution centers  
          Warranty: 20 years  
          Product ID: UL1449 2nd edition,   cUL, UL1283  
          Quality manufacturers: ISO9001: 1994 quality management   certificate BSI FM 30833  
           
          Mechanical performance parameters  
          Shell:   spray-painted steel structure, all-weather; protection rating NEMA 4 (IP66)  
          Fixed: built-wear and multi-point lead pipe fixed angle  
          Connect: # 10   AWG (6 mm2) multi-strand wire  
          Weight: PTX: about 3 kilograms (7 pounds),   PTE: about 5.5 kg (12 lbs)  
          Operating temperature:-400C - 650C  
           
          Electrical performance parameters  
          Protected Mode: All mode   (three-phase Y-10 model): LN, LL (differential mode), LG, NG (common mode)  
          The frequency of input power: PTX :47-420 Hz; PTE and-SD :47-64 Hz  
          Response time: PTX £ 1 nanosecond, PTE <1 nanosecond  
          Capacitance:   PTE: for each mode of <10 μF  
          Diagnosis of instructions: instructions for   each LED with normal lights. Remote alarm interface (C-type dry-type normally   open normally closed contact)  
          Short-circuit current protection: 200 kAIC the   30 amps fuse R-class (the factory does not provide)  
          Maximum EMI / RFI   attenuation-Mil-std-220  
            
              
                
                  | 1   kHz  | 
                  10   kHz  | 
                  100   kHz  | 
                  1 MHz | 
                  10MHz  | 
                  Maximum   attenuation frequency | 
                 
                
                  | 3 dB | 
                  20 dB | 
                  40 dB | 
                  23 dB | 
                  7 dB | 
                  40 dB  @115   kHz | 
                 
              
             
             
            Options  
            Dynamic Tracking Network   (ATN ): PTE  
            The voice of alarm, surge counter and Phase Monitor (SMARTTM   )::(- SD suffix)  
            NEMA Type 4X stainless steel enclosure: (-SS suffix) (prior   notice to the factory, there are at least the number of requirements)  
            Built-in fuse: (-L suffix) (up-to-date drawings at Division I)  
            Built-melting filament switch: (-D suffix) (up-to-date drawings at Division   I)  
            ARM-3 Remote Alarm Module | 
       
      
        | 
               PTX080/PTE080 
              PTX080-3Y201 
              | 
        Summary of technical parameters  
          Pass the peak   flow capacity: Each phase 80KA, each model 40KA  
          ANSI / IEEE C62.41   installation location: A, B and C  
          Applications: high-to low-surge level of   activity areas, sensitive / important electrical loads including the allocation   of cabinet, counter and important user load distribution centers  
          Warranty:   20 years  
          Product ID: UL1449 2nd edition, cUL, UL1283  
          Quality   manufacturers: ISO9001: 1994 quality management certificate BSI FM 30833 
           
          Mechanical performance parameters  
          Shell: spray-painted steel   structure, all-weather; protection rating NEMA 4 (IP66)  
          Fixed: built-wear   and multi-point lead pipe fixed angle  
          Connect: # 10 AWG (6 mm2) multi-strand   wire  
          Weight: about 3 kilograms (7 pounds)  
          Operating temperature:-400F   (-400C) - +1850 F (+850 C) 
           
          Electrical performance parameters  
          Protected Mode: All mode, (three-phase Y-10 model) LN, LL (differential   mode), LG, NG (common mode)  
          The frequency of input power: PTX :47-420 Hz;   PTE and-SD :47-64 Hz  
          Response time: PTX £ 1 nanosecond, PTE <1 nanosecond  
          Capacitance: PTE: for each mode of <10 μF  
          Diagnostic instructions:   LED instructions, each of the normal green, Remote Alarm Interface (C-type   dry-type normally open normally closed contact)  
          Short-circuit current   protection: 200 kAIC the 30 amps fuse R-class (the factory does not provide) 
           
          Maximum EMI / RFI attenuation-Mil-std-220
          
           
            
              
                | 1   kHz  | 
                10   kHz  | 
                100   kHz  | 
                1   MHz | 
                10MHz  | 
                Maximum   attenuation frequency  | 
               
              
                | 3 dB | 
                21 dB | 
                40 dB | 
                23 dB | 
                8 dB | 
                40 dB  @113   kHz | 
               
            
           
         
           
          Options  
            Dynamic Tracking   Network (ATN ): PTE  
            The voice of alarm, surge counter and Phase Monitor   (SMARTTM )::(- SD suffix)  
            NEMA Type 4X stainless steel enclosure: (-SS   suffix) (prior notice to the factory, there are at least the number of   requirements)  
            Built-in fuse: (-L suffix) (up-to-date drawings at Division I)  
            Built-melting filament switch: (-D suffix) (up-to-date drawings at Division   I)  
            ARM-3 Remote Alarm Module 
                      | 
       
      
        | 
             PTE080-3Y201 
              PTE080-3Y201-S/SD
                | 
       
      
        | 
                
           PTX160/PTE160  PTX160-3Y201  | 
        Summary of technical parameters  
          Pass the peak flow capacity: Each phase   160KA, each model 80KA  
          ANSI / IEEE C62.41 installation location: A, B and C  
          Applications: high-to low-surge level of activity areas, sensitive and   important counters the load including the allocation of power, the user   distribution and the main load center cabinet  
          Warranty: 20 years  
          Product   ID: UL1449 2nd edition, cUL, UL1283  
          Quality manufacturers: ISO9001: 1994   quality management certificate BSI FM 30833  
           
          Mechanical performance   parameters  
          Shell: spray-painted steel structure, all-weather; protection   level NEMA4 (IP66)  
          Fixed: built-wear and multi-point lead pipe fixed angle  
          Connect: # 10 AWG (6 mm2) multi-strand wire  
          Weight: about 5.5 kg (12   lbs)  
          Operating temperature:-400F (-400C) - +1850 F (+850 C)  
           
          Electrical performance parameters  
          Protected Mode: All mode,   (three-phase Y-10 model) LN, LL (differential mode), LG, NG (common mode)  
          The frequency of input power: PTX :47-420 Hz; PTE and-SD :47-64 Hz  
          Response time: PTX £ 1 nanosecond, PTE <1 nanosecond  
          Capacitance:   PTE: for each mode of <10 μF  
          Diagnostic instructions: LED instructions,   each of the normal green, Remote Alarm Interface (C-type dry-type normally open   normally closed contact)  
          Short-circuit current protection: 200 kAIC the 30   amps fuse R-class (the factory does not provide)  
          Maximum EMI / RFI   attenuation-Mil-std-220          
           
            
              
                | 1 kHz  | 
                10 kHz  | 
                100 kHz  | 
                1 MHz | 
                10MHz  | 
                Maximum   attenuation frequency  | 
               
              
                | 3 dB | 
                21 dB | 
                40 dB | 
                21 dB | 
                5 dB | 
                40 dB    @98kHz | 
               
            
           
           
          Options  
          Dynamic Tracking Network   (ATN ): PTE  
          The voice of alarm, surge counter and Phase Monitor (SMARTTM   )::(- SD suffix)  
          NEMA Type 4X stainless steel enclosure: (-SS suffix) (prior   notice to the factory, there are at least the number of requirements)  
          Built-in fuse: (-L suffix) (up-to-date drawings at Division I)  
          Built-melting filament switch: (-D suffix) (up-to-date drawings at Division   I)  
          ARM-3 Remote Alarm Module
  | 
       
      
        | 
             PTE160-3Y201 
              PTE160-3Y201-D/SD  | 
       
      
            
                  PTX300/PTE300  PTX300-3Y201  | 
        Summary of technical parameters  
          Pass the peak flow capacity: Each phase   300KA, each model 150KA  
          ANSI / IEEE C62.41 installation location: B and C  
          Applications: high-surge level of activity zones, industrial applications,   including large-capacity into line counters, high-capacity distribution of   electrical cabinets and a single large load  
          Warranty: 20 years  
          Product   ID: UL1449 2nd edition, cUL, UL1283  
          Quality manufacturers: ISO9001: 1994   quality management certificate BSI FM 30833  
           
          Mechanical performance   parameters  
          Shell: spray-painted steel structure, all-weather; protection   level NEMA4 (IP66)  
          Fixed: built-wear and multi-point lead pipe fixed angle  
          Connect: # 14-1/0 (2.5-50mm2) multi-strand wire  
          Weight: about 14   kilograms (30 pounds)  
          Operating temperature:-400F (-400C) - +1850 F (+850 C)  
           
          Electrical performance parameters  
          Protected Mode: All mode,   (three-phase Y-10 model) LN, LL (differential mode), LG, NG (common mode)  
          The frequency of input power: PTX :47-420 Hz; PTE and-SD :47-64 Hz  
          Response time: PTX £ 1 nanosecond, PTE <1 nanosecond  
          Capacitance:   PTE: for each mode of <10 μF  
          Diagnostic instructions: LED instructions,   each of the normal green, Remote Alarm Interface (C-type dry-type normally open   normally closed contact)  
          Short-circuit current protection: 200 kAIC the RK5   fuse 60 amps (the factory does not provide) the maximum EMI / RFI   attenuation-Mil-std-220
                   
            
              
                | 1 kHz  | 
                10 kHz  | 
                100 kHz  | 
                1 MHz | 
                10MHz  | 
                Maximum attenuation   frequency  | 
               
              
                | 3 dB | 
                21 dB | 
                40 dB | 
                22 dB | 
                6 dB | 
                40 dB  @   108kHz | 
               
            
           
           
          Options  
          Dynamic Tracking Network   (ATN ): PTE  
          The voice of alarm, surge counter and Phase Monitor (SMARTTM   )::(- SD suffix)  
          NEMA Type 4X stainless steel enclosure: (-SS suffix) (prior   notice to the factory, there are at least the number of orders required)  
          Built-in fuse: (-L suffix) (up-to-date drawings at Division I)  
          Built-melting filament switch: (-D suffix) (up-to-date drawings at Division   I)  
          ARM-3 Remote Alarm Module
  | 
       
      
        | 
             PTE300-3Y201
                PTE300-3Y201-D/SD 
           PTX300-3Y201-D/SD  | 
       
      
        | 
              PTX400/PTE400  PTX400-3Y201 
          
           PTE400-3Y201 
           PTE400-3Y201-D/SD  | 
        Summary of technical parameters  
          Pass the peak flow capacity: Each phase   400KA, each model 200KA  
          ANSI / IEEE C62.41 installation location: B and C  
          Applications: high-surge level of activity zones, industrial applications,   including large-capacity into line counters, high-capacity distribution of   electrical cabinets and a single large load  
          Warranty: 20 years  
          Product   ID: UL1449 2nd edition, cUL, UL1283  
          Quality manufacturers: ISO9001: 1994   quality management certificate BSI FM 30833  
           
          Mechanical performance   parameters  
          Shell: spray-painted steel structure, all-weather; protection   level NEMA4 (IP66)  
          Fixed: built-wear and multi-point lead pipe fixed angle  
          Connect: # 14-1/0 (2.5-50mm2) multi-strand wire  
          Weight: about 14.5   kilograms (32 pounds)  
          Operating temperature:-400F (-400C) - +1850 F (+850 C)  
          Electrical performance parameters  
          Protected Mode: All mode, (three-phase   Y-10 model) LN, LL (differential mode), LG, NG (common mode)  
          The frequency   of input power: PTX :47-420 Hz; PTE and-SD :47-64 Hz  
          Response time: PTX £ 1   nanosecond, PTE <1 nanosecond  
          Capacitance: PTE: for each mode of <10   μF  
          Diagnostic instructions: LED instructions, each of the normal green,   Remote Alarm Interface (C-type dry-type normally open normally closed contact)  
          Short-circuit current protection: 200 kAIC the RK5 fuse 100 amps (the   factory does not provide)  
          Maximum EMI / RFI attenuation-Mil-std-220
                   
            
              
                | 1   kHz  | 
                10   kHz  | 
                100   kHz  | 
                1 MHz | 
                10MHz  | 
                Maximum attenuation   frequency  | 
               
              
                | 3 dB | 
                21 dB | 
                40 dB | 
                22 dB | 
                6 dB | 
                40 dB  @   108kHz | 
               
            
           
           
          Options  
            Dynamic Tracking   Network (ATN ): PTE  
            The voice of alarm, surge counter and Phase Monitor   (SMARTTM )::(- SD suffix)  
            NEMA Type 4X stainless steel enclosure: (-SS   suffix) (prior notice to the factory, there are at least the number of   requirements)  
            Built-in fuse: (-L suffix) (up-to-date drawings at Division I)  
            Built-melting filament switch: (-D suffix) (up-to-date drawings at Division   I)  
            ARM-3 Remote Alarm Module 
            | 
       
      
        | 
              PTX640/PTE640 
           PTX640-3Y201/PTE640-3Y201 
           PTX640-3Y201-S/D 
           PTE640-3Y201-D/SD 
             
              | 
        Summary of technical parameters  
          Pass the peak flow capacity: Each phase   640KA, each model 320KA  
          ANSI / IEEE C62.41 installation location: B and C  
          Applications: high-surge level of activity zones, industrial applications,   including large-capacity into line counters, high-capacity distribution of   electrical cabinets and a single large load  
          Warranty: 20 years  
          Product   ID: UL1449 2nd edition, cUL, UL1283  
          Quality manufacturers: ISO9001: 1994   quality management certificate BSI FM 30833  
           
          Mechanical performance   parameters  
          Shell: spray-painted steel structure, all-weather; protection   level NEMA4 (IP66)  
          Fixed: built-wear and multi-point lead pipe fixed angle  
          Connect: # 14-1/0 (2.5-50mm2) multi-strand wire  
          Weight: about 14.5   kilograms (32 pounds)  
          Operating temperature:-400F (-400C) - +1850 F (+850 C)  
          Electrical performance parameters  
          Protected Mode: All mode, LN, LL   (differential mode), LG, NG (common mode)  
          The frequency of input power: PTX   :47-420 Hz; PTE and all-SD :47-64 Hz  
          Response time: PTX £ 1 nanosecond, PTE   <1 nanosecond  
          Capacitance: PTE: for each mode of <10 μF  
          Diagnostic   instructions: LED instructions, each of the normal green, Remote Alarm Interface   (C-type dry-type normally open normally closed contact)  
          Short-circuit   current protection: 200 kAIC the RK5 fuse 100 amps (the factory does not   provide)  
          Maximum EMI / RFI attenuation-Mil-std-220
                   
            
              
                | 1   kHz  | 
                10   kHz  | 
                100   kHz  | 
                1 MHz | 
                10MHz  | 
                Maximum   attenuation frequency  | 
               
              
                | 3 dB | 
                21 dB | 
                40 dB | 
                22 dB | 
                6 dB | 
                40 dB  @   108kHz | 
               
            
           
           
          Options  
          Dynamic Tracking Network   (ATN ): PTE  
          The voice of alarm, surge counter and Phase Monitor (SMARTTM   )::(- SD suffix)  
          NEMA Type 4X stainless steel enclosure: (-SS suffix) (prior   notice to the factory, there are at least the number of requirements)  
          Built-in fuse: (-L suffix) (up-to-date drawings at Division I)  
          Built-melting filament switch: (-D suffix) (up-to-date drawings at Division   I)  
          ARM-3 Remote Alarm Module
  | 
       
     
     | 
 |