    First, product performance and   characteristics of  
       
                 
      Electrolytic Ion Ground used by   our foreign technology, self-development, production and implementation of   services and technical support to a new type of ground material.  
      Electrolytic Ion Ground ion tube filled with high-carbon compound crystals,   the appearance of the use of copper, two kinds of steel materials. To ensure the   best possible performance and longer service life of electrical conductivity.   Conductor internal filling material containing a special ion compounds, can   fully absorb the moisture in the air. Through deliquescence role of ionizing   effective activity released into the soil, and soil and moisture in the air with   more to promote the release down the outside conductor resistance, and   resistance to maintain long-term stability. Conductor within the compounds, with   the passage of time and gradually extend the synthesis of transparent gelatinous   state. We use the conductive properties of glial compounds so that the whole   system to a long-term in the state of ion exchange in order to constitute an   ideal ground electrode electrolytic ion.  
       
        Second, the   transformation from traditional grounding process, the ions are characterized by   very grounding 
         
         
         
      Third, the working principle  
         
                      
        Electrolytic Ion Ground added to the ground electrode reversible filler release.   This filler has a water-absorbent, water, characteristic of reversible. Water   when it can absorb 100-500 times their own water, when the external environment   when the dry water and can be fully owned by the release of water to the   surrounding water balance, such a reversible reaction, the effective shell   environment to ensure the effective humidity, to ensure the stability of the   grounding resistance. Generated in this way the earth ions absorb moisture, you   can role through the deliquescence will be effective plasma electrolytic   activity released into the surrounding soil, so that as a very grounding ion   generation device, so as to improve the soil around the ground to meet the   requirements. Ground electrode through the external filler filler with its   internal electrolytic ion interaction for the shell of the chemical treatment of   soil to reduce soil resistivity shell, at the same time very grounded in the   sustained-release between the earth and soil to form a transitional zone, ground   electrode increases the equivalent cross-sectional area and soil contact area,   eliminating the grounding and contact resistance between the soil and improved   the way the electric field distribution, the infiltration of filler good   performance, deep into the soil and chimney in to form roots network, to   increase the size of the discharge. 
         
          
         
       
      1,   electrolytic ion ground electrode 2, the existing soil 3, special filler  
      4,   the proliferation of the surrounding ion 5, the electrical conductivity of soil   to expand the scope of  
       
      Fourth, product technical   parameters  
       
            
       
      Fifth, the design method and the number of reference  
         
        The projection formula: n ≈ (0.0275   * ρ / R) -0.4  
        n order to support the required number of grounding electrodes  
        soil resistivity ρ  
        Maximum value for the grounding resistance R  
        If   the soil is particularly high resistivity (1000 ohm. M), can be calculated by   multiplying the above-mentioned adjustment factor k, can be value 1.2 ~ 1.5, a   high soil resistivity, k values increased. 
         
         
           
 
      Sixth, the scope of application and how to use  
           
                    
        Electrolytic Ion Ground very good because of its   antiseptic properties, excellent electrical conductivity properties and a unique   design process, are widely used in telecommunications, electric power,   petrochemical, financial, network, electronics and other important places of the   ground works, especially for poor soil conditions, construction limited   conditions, the technical standards for the ground engineering requirements.  
         
        Construction method  
         
        1. Drilling:  
        Construction site in the   selected diameter of 160mm × 3150mm/1550mm drilled vertical holes in the ground.  
        2. The preparation of filler:  
        Blending water into paste-like filler   (slightly viscous fluid was like) into a good pre-drilled holes, the depth of   some hole-bit;  
        3. Ground electrode implant:  
        (1) opened to great seal   tape;  
        (2) holes in the ground electrode implantation, the top ground   electrode flush with the ground plane;  
        (3) take good pinout;  
        (4) filler   to fill in the rest of the surrounding earth to earth only when the top 100mm,   measuring grounding resistance to ground requirements, covered with soil to fill   around the electrode.  
        Note: When a ground electrode not to stop when   requested, can be used in parallel use of two sets or more, stick with the stick   should not be less than the interval between 5M; pinout use of multi-strand   copper wire 50mm2, pinout and the ground electrode Press-fit body to implement,   contact embalmed.  
       | 
 |