German dehn Power Arrester German dehn Signal SPD |
|
German Power Supply arrester lightning arrester lightning arrester device three-phase power supply Lightning Box |
|
|
B-class lightning protection device (power a lightning protection device) Strong Weak lightning lightning electric three-phase / single phase power supply arrester Lightning Box |
Model |
portmaxi |
gap B |
Test is based on |
|
E DIN VDE 0675-6:1989-11和-6/A1:1996-03 |
Rated (maximum continuous voltage) |
UC |
255V/50Hz |
440V/50Hz |
255V/50HZ |
UCThe maximum allowable size |
If |
4KArms |
750KArms |
100KArms |
Lightning pulse single-phase flow (10/350) two-phase or multiphase |
Uimp |
75KA |
100KA |
100KA |
Voltage protection level (1.2/50) |
UP |
<3.5KA |
<4KA |
Response Time |
tA |
<100ns |
<100ns |
Maximum fuse intensity |
|
350A gL/gG |
63A gL/gG |
|
Short-circuit current intensity |
|
50KA/50Hz |
25KA/50Hz |
|
Working temperature range |
|
-400C...+800C |
|
Insulation resistance |
Risol |
>103MΩ |
|
|
|
|
C-arrester(Power 2 SPD)
Three-phase / single phase power supply lightning arrester Lightning Power Supply Box |
Model |
|
guard...230/400 |
gap C/T |
|
|
150 |
275 |
320 |
385 |
440 |
600 |
|
Testing standards |
|
E DIN VDE 0675-6:1989-11,-6/A1:1996-03 |
Rated Maximum continuous voltage |
UC |
150V~ |
275V~
350V- |
320V~
420V- |
385V~
500V- |
440V~
585V- |
600V~
600V- |
255V/50Hz |
Nominal discharge current |
isn |
15KA |
20KA |
15KA |
20KA |
Maximum discharge current |
Imax |
40KA |
If 200Arms |
Protection
Level |
5KA(8/20) |
UP
< |
550V |
1KV |
1250V |
1500V |
1750V |
2.5KV |
|
Isn |
750V |
1.5KV |
1750V |
2000V |
2250V |
3KV |
1500V |
Response Time |
tA |
<25ns |
<100ns |
Maximum fuse intensity |
|
125A gL/gG |
100A gL/gG |
|
Short-circuit current intensity |
|
50KA/50Hz |
25KA/50Hz |
|
Temperature |
|
-400C...+800C-400C...+800C |
Remote Alarm Terminal Type |
|
Event type |
Rated terminal power |
UN/IN |
AC:250V/0.5A DC:250V/0.1A 125V/0.2A 75V/0.5A
|
Remote Alarm wire cross-section |
|
Maximum 1.5mm2Single-strand wire |
Maximum 1.5mm2Single-strand wire |
|
|
|
D Grade Surge Protector(Power 3 SPD) Surge Suppressor single-phase power three-phase power supply arrester lightning arrester |
rail 230/3N FML(Three-phase power SPD) rail 230 FML(Single-phase power SPD) |
Test is based on |
|
E DIN VDE 0675-6:1989-11和-6/A1:1996-03 |
Nominal Voltage |
UN |
230V~/400V~ |
Rated voltage (maximum continuous operating voltage) |
UC |
255V~/440V~ |
Nominal Current |
iN |
16A |
Nominal discharge current(8/20)
|
isn |
LÞN,LÞL 3KA NÞPE 5KA |
Complex Waveform |
Uoc |
LÞN,LÞL 6KV NÞPE 10KV |
Voltage protection level |
UP |
LÞN<1.25KV L(N)ÞPE<1.5KV LÞL<2.5KV |
Response Time |
tA |
LÞN<25ns L(N)ÞPE<100ns |
Maximum fuse intensity |
|
16AgL/gG or C16A |
Temperature |
|
-400C...+800C |
Installation width |
|
3 standard modules wide and meets the specifications DIN 43880 |
Remote Alarm Terminals |
|
Normally Open contact |
Rated terminal power |
UN/IN |
AC:250V/0.5A DC:250V/0.1A 125V/0.2A 75V/0.5A |
Remote Alarm conductor cross-section |
|
1.5mm2Single-strand wire |
|
|
|
Composite arrester/SPD
VGA280 / 4, VGA280 / 2 Power Lightning Protection Box |
Specifications: |
ventil |
|
VGA280/4 |
VGA280/2 |
Testing standards |
|
E DIN VDE 0675-6:1989-11 |
Rated voltage (maximum continuous voltage) |
UC |
280V/50Hz |
Nominal discharge current (8 / 20) |
isn |
5KA |
Lightning impulse current (8 / 80) |
Iimp |
100KA |
Voltage protection level residual voltage isn pm
Lightning impulse impulse voltage 1.2/50 |
UP |
<2.5KV
<4KV |
Response Time |
tA |
<25ns |
Maximum fuse intensity |
|
100AgL/gG |
Short-circuit current intensity |
|
25KA/50Hz |
Temperature |
|
-400C...+800C |
|
Composite lightning /
SPD ventil VGA280 Lightning surge protector for the power line access lightning equipotential system, can be resolved in one location, separate power supply mine B, C grade. Used to protect low-voltage devices, surge suppression, and even a direct lightning strike protection。
|
|
|
|
|
|
|
|
|