繁体中文
ENGLISH
简体中文

 About   Products  service  Consultation   Contact

 
Products Series
Lightning
Satellite early discharge lightning rod
Apollo active lightning
IF3 pre-discharge lightning rod
INDELEC early discharge lightning rod
INGESCO early discharge lightning rod
Surge Protective Device
Germany OBO lightning protection devices
Germany DEHN SPD
British FURSE SPD
U.S. PANAMAX Surge Protector
U.S. Eaton Innovative Surge Protection Device
Grounding Products
ETC earthing module
Resistance Reducing Agent
Electrolytic Ion Ground Pole
MTL Industrial Products

mtl Surge Protector
 
 
German dehn Power Arrester         German dehn Signal SPD
     
 

German arrester, lightning protection devices, lightning arrester signal devices, signal surge arrester, surge protector

 

Twisted-pair arrester, lightning arrester line of control, DC arrester, surge protector BLITZDUCTOR VT

Model   TTY RS485 GS AD 24-
Nominal Voltage UN 24V- 5V- 110V~ 24V
Voltage UC 26.8V- 6V- 170V- 35V-
Nominal Current iN 100mA 500mA 250mA 10A
Nominal discharge current (8 / 20) isn 10KA
isnVoltage ProtectionLevel Line / Line UP 50V  30V 800V <70V
Line / ground 700V 700V 600V <700V
the voltage 1KV/us
Protection level
Line / Line UP 36V 8.5V 800V <50V
Line / ground 600V 600V 600V <700V
Response Time Line / Line ta 1ns 100ns <1ns
Line / ground <100ns <100ns
Bandwidth fG 1MHz 18MHz  
Series resistance R 17.2W/ELA 1.8W/Thread 10W/Thread  
Parallel capacitor C 1nF 3nF 10pF 7nF
Working temperature range   -25OC...+80OC -25...+80
Conductor cross-section  

Maximum 2.5mm

Mounting brackets   35mm standard rail, according to EN50022
信号避雷器- VT/TTY
vt/tty/485
 
KAZ10
 
link
 
Serial Protector
 
 

Twisted-pair lightning, the information line arrester, surge protector CT MD Blitzductor CT

Model   MD(E) MD(E) MD(E) MD(E) MD(E) MD(E) MD(E) MD(E) MD(E)
Item   919 540 919 541 919 542 919 543 919 544 919 545 919 546 919 547 919 549
Nominal Voltage UN 5V- 12V- 15V- 24V- 30V- 48V- 60V- 110V- 250V-
Voltage UC 6.0V-
4.2V~
14.5V-
10.2V~
17.8V-
12.5V~
26.8V-
18.9V~
34.8V-
24.5V~
55.1V-
38.9V~
65V-
50V~
170V-
130V~
280V-
190V~
Nominal Current iN 1A
Nominal release Electric Current Each line isn 10KA
Bus 10KA 20KA
Maximum current   20KA
isn
Voltage Protection
Line / Line UP 15V 27V 32V 45V 60V 85V 110V 360V 630V
1KV/us
the voltage
Line / Line UP 8V 19V 24V 35V 50V 75V 90V 260V 490V
Line / ground 600V 700V
Coordination properties X/1 X/2

Response Time
Line / Line ta 1ns 25ns
Line / ground 100ns
Bandwidth fG 1MHz 3MHz 4MHz 5.3MHz 6MHz 9MHz 11MHz 12MHz 15MHz
Series resistance R 1W 1.5W 1.8W 1.8W 1.8W 1.8W 1.8W - -
Connector size C Maximum 2.5mm2
Working temperature range   -25...+80
Size   12mm wide, 58mm high

Information Line SPD, Video arrester, arrester feeders, data-line surge arresters, network SPD UGKF

Model   BNC N-L B-L Twinax RJ45 TP
Nominal Voltage UN 5V- -8V-/+1V- 2.4V- 5V-
Rated voltage UC 8V -10V-/+14V- 2.8V- 6V-
Nominal discharge current(8/20) iSN

2.5KA(A/S)

20KA(S/PG)

5KA

10KA(S/PG)

300A(AA)300A(A/PG)

2.5A(S/PG)

Maximum discharge current(8/20) Imax

5KA(A/S)

20KA(S/PG)

10KA(A/S)

20KA(S/PG)

400A(AA)400A(A/PG)

5KA(S/PG)

isn the voltage protection level Up

<25V(A/S)

<20V(A/S)

<35V(A/S)

<15V(A/S)

<35V<A/A)<35V(A/PG)

1KV/us the voltage protection level Up

<13V(A/S)

<15V(A/S)

<13V(A/S)

<13V(A/A)<13V(A/PG)

<700V(A/S)

<600V((A or S/PG)

Response Time tA

<1ns(A/S)

<100ns(S/PG)

<1ns(A/S)

<25ns(S/PG)

<1ns (A/S)<100ns(S/PG)

Bandwidth fG 300MHz 90MHz 300MHz 35MHz 165MHz
Data Transfer Rate Vs 16Mbps 2Mbps 155Mbps

Input(Socket)

Output(Socket)

 

BNC

BNC

N

N

BNC

BNC

Twinax

Twinax

Shielded

RJ 45Crystal Head

Shield Ground    Through the spark gap and the outside0.75mm2Indirect grounding conductor

Diameter

Length

  

Φ24mm

74mm

25mm

90mm

Φ24mm

74mm

25mm

114m

25mm

74mm

Antennas Protector , Communications, lightning protection devices, high-frequency lightning protection devices, RF arrester, coaxial lightning arrester UGK
Model   UGK/B UGK/N UGK/U
Rated voltage (maximum continuous operating voltage) UC 250V- 250V- 450V-
Nominal Current IN 2.5A 3.5A 5A
Lightning test current (10/350) Iimp 0.8KA 0.5KA
Nominal discharge current (8 / 20) isn 15KA 5KA
Maximum discharge current(8/20) Imax 30KA 10KA
1KV/µs the voltage protection level UP 2.5KV 700KV 1100KV
Frequency upper limit   500MHz 2GHz 300MHz
The output power UT 250W 500W 1.2KW
Insertion Loss aE <0.2dB <0.5dB 0.1dB
Return Loss aR 20dB
Impedance Z 50/75/93Ω 50Ω

Classification test is based onE DIN

EN 61644-1:1999-07

 

 

A2, B2, C2, C3, D1

Grounding   Welding sheet through cable

Size

 

F24mm 4mm

25mm 70mm

25mm 75mm

Ports   BNC N UHF


 About   Products  service  Consultation   Contact

Products Navigation: Lightning SPD lightning arrester lightning rod lightning conductor transient protection ESE lightning conductor
Address: 19D, Hengyunhaoting
2Building,Fuhua 3Road,Shenzhen,PRC.Postcode: 518033
E-mail:sales@08lightning.com Tel:0755-88834928 88834938 Fax:0755-88834938 Mobile:18929315088 粤ICP备05124982号-6